Open-Switch and Open-Phase Real Time FDI Process for Multiphase PM Synchronous Motors. Open-Switch and Open-Phase Real Time FDI Process for Multiphase PM Synchronous Motors

Archive ouverte : Communication dans un congrès

Nguyen, Ngac Ky | Meinguet, Fabien | Trabelsi, Mohamed | Semail, Eric | Ngac, Ky | Nguyen, Fabien

Edité par HAL CCSD ; ISIE Conference

This paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric drive system has particular operating characteristics either in healthy states or in the faulty ones. Two original contributions are considered in this paper. They consist in normalizing the input variables of the FDI process applied to multiphase system and compensating the noise (switching and sensors noises) and dccomponent resulting from the fault occurrence. The proposed strategy uses multiple normalized criterias derived from the measured phase currents and the references currents obtained from the outputs of the speed controllers. The FDI shows independence with respect to transient states and to switching and measurement noises. Moreover, it can be easily included in an existing software without any additional sensors. The validity of the proposed method is verified by Matlab/Simulink simulation tests.

Consulter en ligne

Suggestions

Du même auteur

Experimental Investigation of Inverter Open-Circuit Fault Diagnosis for Bi-Harmonic Five-Phase Permanent Magnet Drive | Trabelsi, Mohamed

Experimental Investigation of Inverter Open-Circuit Fault Diagnosis for Bi-...

Archive ouverte: Article de revue

Trabelsi, Mohamed | 2017

International audience. This paper proposes a procedure that is suitable for experimental investigation of real-time open-switch and open-phase faults diagnosis of a five-leg Voltage Source Inverter (VSI) feeding a ...

Real-Time Switches Fault Diagnosis Based on Typical Operating Characteristics of Five-Phase Permanent Magnetic Synchronous Machines | Trabelsi, Mohamed

Real-Time Switches Fault Diagnosis Based on Typical Operating Characteristi...

Archive ouverte: Article de revue

Trabelsi, Mohamed | 2016

International audience. A novel centroid-based diagnostic method of the power switches in five-leg Voltage Source Inverter (VSI) is proposed in this paper. Using a vectorial multi-machine description, a five-phase d...

Sensorless Control for Non-sinusoidal Five-phase Interior PMSM based on Sliding Mode Observer | Mini, Youssouf

Sensorless Control for Non-sinusoidal Five-phase Interior PMSM based on Sli...

Archive ouverte: Article de revue

Mini, Youssouf | 2021-12

International audience. This paper proposes a sensorless control strategy based on Sliding Mode Observer (SMO) for a Five-phase Interior Permanent Magnet Synchronous Machine (FIPMSM), with a consideration of the thi...

Du même sujet

Inverter Open Circuit Faults Diagnosis in Series-Connected Six-Phases Permanent Magnet Drive | dos Santos Moraes, Tiago José

Inverter Open Circuit Faults Diagnosis in Series-Connected Six-Phases Perma...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2017-08

This work is a part of a project CE2I supported by FEDER and by the regional council of Hauts de France Region. It has been also supported by Thales Alenia Space.. International audience. This paper deals with the f...

Open Switch Fault Effects Analysis (OSFEA) in Five Phase PMSM Designed for Aerospace Application | Trabelsi, Mohamed

Open Switch Fault Effects Analysis (OSFEA) in Five Phase PMSM Designed for ...

Archive ouverte: Communication dans un congrès

Trabelsi, Mohamed | 2016-06-22

International audience. This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For t...

Comparison and Analysis of Post-Fault Operation Modes in a Five-Phase PMSM Considering Thermal Behavior | Zahr, Hussein

Comparison and Analysis of Post-Fault Operation Modes in a Five-Phase PMSM ...

Archive ouverte: Communication dans un congrès

Zahr, Hussein | 2018-04-10

International audience. This paper presents a comparative evaluation of fault tolerant control strategies for a five-phase Permanent Magnet Synchronous Machine (PMSM) under an opened-phasefault mode. Two main classi...

Flux-Weakening Strategies for a Five-Phase PM Synchronous Machine | Lu, Li

Flux-Weakening Strategies for a Five-Phase PM Synchronous Machine

Archive ouverte: Communication dans un congrès

Lu, Li | 2011-09

International audience. In order to get a low cost mild hybrid system, a global objective is to keep the actual thermal engine architecture. As consequence, the current clawpole synchronous automotive generator must...

High fidelity closed loop controlled friction in SMARTTAC tactile stimulator | Ben Messaoud, Wael

High fidelity closed loop controlled friction in SMARTTAC tactile stimulato...

Archive ouverte: Communication dans un congrès

Ben Messaoud, Wael | 2015-09-08

International audience. The present study investigates the implementation of a closed loop control in a new smart tactile stimulator called “SMARTTAC”. This haptic device is able to stimulate the fingertip in order ...

Demagnetization analysis of an open-end windings 5-phase PMSM under transistor short-circuit fault | dos Santos Moraes, Tiago José

Demagnetization analysis of an open-end windings 5-phase PMSM under transis...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2019-10-14

International audience. For an open-end windings integrated Permanent Magnet Synchronous Machine, the demagnetization of the permanent magnets is analyzed when a transistor is short-circuited and no specific control...

Chargement des enrichissements...