Real-Time Switches Fault Diagnosis Based on Typical Operating Characteristics of Five-Phase Permanent Magnetic Synchronous Machines

Archive ouverte : Article de revue

Trabelsi, Mohamed | Nguyen, Ngac-Ky | Semail, Eric

Edité par HAL CCSD

International audience. A novel centroid-based diagnostic method of the power switches in five-leg Voltage Source Inverter (VSI) is proposed in this paper. Using a vectorial multi-machine description, a five-phase drive presenting an opened switch or an opened phase faults has typical operating characteristics in comparison to classical three-phase drives. Based on such characteristics, this work aims to provide a simple and robust diagnostic process for switches fault regardless of the shape of the back-EMFs (harmonic components) and the transient states due to the load variation. Original theoretical developments are presented. Experimental results are shown to validate the proposed strategy

Consulter en ligne

Suggestions

Du même auteur

Open Switch Fault Effects Analysis (OSFEA) in Five Phase PMSM Designed for Aerospace Application | Trabelsi, Mohamed

Open Switch Fault Effects Analysis (OSFEA) in Five Phase PMSM Designed for ...

Archive ouverte: Communication dans un congrès

Trabelsi, Mohamed | 2016-06-22

International audience. This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For t...

A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under Short-Circuit Inverter Switch Fault | dos Santos Moraes, Tiago José

A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2015-06

International audience. This paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in...

Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives | Meinguet, Fabien

Signal-based Technique for Fault Detection and Isolation of Inverter Faults...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2012-12-17

International audience. A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitabl...

Du même sujet

Investigation on Model Predictive Control of a Five-Phase Permanent Magnet Synchronous Machine under Voltage and Current limits | Kestelyn, Xavier

Investigation on Model Predictive Control of a Five-Phase Permanent Magnet ...

Archive ouverte: Communication dans un congrès

Kestelyn, Xavier | 2015-03

The optimal control of electrical drives necessitates to take into account current and voltage limits that are imposed by the power electronics and the electrical machines. Let’s cite for example the flux-weakening operation of el...

Real-Time Validation of a Cascaded Model Predictive Control Technique for a Five-Phase Permanent Magnet Synchronous Machine Under Current and Voltage Limits | Bermudez Guzman, Mario

Real-Time Validation of a Cascaded Model Predictive Control Technique for a...

Archive ouverte: Communication dans un congrès

Bermudez Guzman, Mario | 2017-07

International audience. Multiphase machines have recently gained importance in the research community for their use in applications where high power density, wide speed range and fault-tolerant capabilities are need...

A Vectorial Approach for Generation of Optimal Current References for Multiphase Permanent-Magnet Synchronous Machines in Real Time | Kestelyn, Xavier

A Vectorial Approach for Generation of Optimal Current References for Multi...

Archive ouverte: Article de revue

Kestelyn, Xavier | 2011-11

International audience. This paper deals with the generation of optimal current references for multiphase permanent-magnet (PM) synchronous machines in normal or fault mode (open-circuited phases). Current reference...

Design and modeling of a 7-phase axial flux permanent magnet synchronous machine: vector control in normal and fault mode operations. Conception et modélisation d'une machine synchrone à 7 phases à aimants permanents et flux axial : commande vectorielle en modes normal et dégradé | Locment, Fabrice

Design and modeling of a 7-phase axial flux permanent magnet synchronous ma...

Archive ouverte: Thèse

Locment, Fabrice | 2006-12-11

For the variable speed drives, the electric machine being no more directly coupled to the three-phase network, the choice of phase number can be reconsidered. We are interested in this thesis in the design of variable speed drives...

Fault-tolerant control of non-sinusoidal multiphase permanent magnet synchronous machine drives under constraints on current and voltage for automotive applications. Commande tolérante aux défauts des entraînements de machines synchrones à aimants permanents polyphasées non-sinusoïdales sous contraintes de courant et de tension pour les applications automobiles | Vu, Duc Tan

Fault-tolerant control of non-sinusoidal multiphase permanent magnet synchr...

Archive ouverte: Thèse

Vu, Duc Tan | 2020-11-24

Electric drives for electrified vehicles need to fulfil some specific requirements from automotive markets such as high efficiency, high volume power and torque densities, low-cost but safe-to-touch, high functional reliability, h...

Model predictive optimal control considering current and voltage limitations: Real-time validation using OPAL-RT technologies and five-phase permanent magnet synchronous machines | Bermudez Guzman, Mario

Model predictive optimal control considering current and voltage limitation...

Archive ouverte: Article de revue

Bermudez Guzman, Mario | 2019-04

International audience. Multiphase machines have recently gained interest in the research community for their use in applications where high power density, wide speed range and fault-tolerant capabilities are requir...

Chargement des enrichissements...