Control reconfiguration of a doubly fed induction machine based wind generator to increase the low voltage ride through capability. Reconfiguration du dispositif de commande d’une éolienne en cas de creux de tension

Archive ouverte : Thèse

Peng, Ling

Edité par HAL CCSD

With the massive development of wind energy, the technical requirements for connecting this technology will require the improvement of the fault ride-through capability of grid-connected wind turbines. The task for the grid system operator is to use all generators to ensure the stability of the electrical system.From a dynamic model of a Doubly Fed Induction Generator (DFIG) based wind generator, an improved vector control has been proposed by taking into account the dynamics of the magnetic flux, which are generated by the voltage dip. The higher performances have been established by comparison with the conventional control method. The operation domain was also determined.During serious voltage dips, a hysteresis control scheme of the active Crowbar is proposed to protect the system within a demagnetization method of the DFIG. Moreover, additional reactive power can be produced both by the MADA and the grid-side converter in order to support the electric network during the grid fault.A space vector hysteresis current control strategy of both three-level converters is proposed to improve the dynamic response of the system and to reduce the parameter variation effects on the control performanceDepending on the grid fault duration, different control objectives have to be achieved with priority to restrain the rotor over-current or to supply reactive power. Then the reconfiguration scheme of the control strategies of high power DFIG wind turbine system is proposed to enhance the fault ride-through capability of the DFIG system. With this specific methodology, the DFIG can stay connected and can supply maximal reactive current during voltage dips to help voltage recovery . Avec le développement de l’éolien, les prescriptions techniques de raccordement de cette technologie obligeront le maintient de sa connexion lors d’incidents sur la tension du réseau électrique. L’enjeu pour le gestionnaire du réseau est de pouvoir utiliser tous les générateurs pour garantir la stabilité du système électrique.A partir d’un modèle dynamique d’une éolienne à base de Machine Asynchrone à Double Alimentation (MADA), une commande vectorielle améliorée a été proposée en prenant en compte la dynamique du flux statorique engendrée par la chute de tension. Les performances supérieures en terme de maintient de la production ont été établies par comparaison avec la méthode de commande classique. Son domaine d’utilisation a été également déterminé.Pendant les creux de tension importants, une protection matérielle (crowbar) est implémentée avec un contrôle de la démagnétisation de la MADA. En outre, de la puissance réactive peut être produite à la fois par la MADA et par le convertisseur connecté au réseau électrique au cours de la défaillance du réseau.Un contrôle vectoriel à hystérésis des courants pour les deux convertisseurs électroniques multiniveaux est proposé et évalué pour améliorer la réponse dynamique de ces convertisseurs et pour réduire les effets des variations des paramètres sur les performances de la commande. Selon la durée du défaut, des objectifs différents de contrôle doivent être réalisés en priorité pour empêcher des surintensités rotoriques et pour fournir de la puissance réactive. Une reconfiguration complète du dispositif de commande de cette éolienne est détaillée pour renforcer le maintient de la production éolienne lors de défaillances

Consulter en ligne

Suggestions

Du même auteur

Improved Crowbar Control Strategy of DFIG Based Wind Turbines for Grid Fault Ride-Through | Peng, Ling

Improved Crowbar Control Strategy of DFIG Based Wind Turbines for Grid Faul...

Archive ouverte: Communication dans un congrès

Peng, Ling | 2009-02-15

International audience

Structurally Flexible Triethanolamine Core PAMAM Dendrimers Are Effective Nanovectors for DNA Transfection in Vitro and in Vivo to the Mouse Thymus | Liu, Xiaoxuan

Structurally Flexible Triethanolamine Core PAMAM Dendrimers Are Effective N...

Archive ouverte: Article de revue

Liu, Xiaoxuan | 2011-12

International audience. With the aim of developing dendrimer nanovectors with a precisely controlled architecture and flexible structure for DNA transfection, we designed PAMAM dendrimers bearing a triethanolamine (...

Du même sujet

Management of a wind farm and integration in the operational power system, Contribution of multilevel power electronic converters for the control of doubly fed induction machine based wind generators. Supervision d’une ferme éolienne pour son intégration dans la gestion d’un réseau électrique, Apports des convertisseurs multi niveaux au réglage des éoliennes à base de machine asynchrone à double alimentation | Ghennam, Tarak

Management of a wind farm and integration in the operational power system, ...

Archive ouverte: Thèse

Ghennam, Tarak | 2011-09-29

This research work deals with two topics conditioning the large scale development of wind turbines into electrical grids. The first is devoted to the development of new algorithms for the control of Doubly Fed Induction Machine (D...

Study of electromechanical energy conversion system of a small hydropower plant with variable speed. Etude du système de conversion électromécanique d'une microcentrale hydroélectrique à vitesse variable | Breban, Stefan

Study of electromechanical energy conversion system of a small hydropower p...

Archive ouverte: Thèse

Breban, Stefan | 2008-12-12

The interest for renewable energy is growing every day, globally. The European Union's objective is to increase, by year 2020, the production of electrical energy from renewable sources with 20% of the total energy consumption. Wi...

Experimental investigation of efficient and simple wind-turbine based on DFIG-direct power control using LCL-filter for stand-alone mode | Francois, Bruno

Experimental investigation of efficient and simple wind-turbine based on DF...

Archive ouverte: Article de revue

Francois, Bruno | 2022-06-01

International audience. If you would prefer to submit your corrections by annotating the PDF proof, please download and submit an annotatable PDF proof by clicking the link below. Annotate PDF ISATRA: 4197 Model 5G ...

Control and energy management of a hybrid active wing generator including energy storage system with super-capacitors and hydrogen technologies for microgrid application. Commande et supervision énergétique d’un générateur hybride actif éolien incluant du stockage sous forme d’hydrogène et des super-condensateurs pour l’intégration dans le système électrique d’un micro réseau | Zhou, Tao

Control and energy management of a hybrid active wing generator including e...

Archive ouverte: Thèse

Zhou, Tao | 2009-06-30

A hybrid power system is studied in this thesis for the distributed generation based on renewable energy resources and energy storage systems in microgrid applications. It consists of a wind generator as primary energy source, sup...

Vent et performances des éoliennes / C.G. Justus | Justus, C. G.. Auteur

Vent et performances des éoliennes / C.G. Justus

Livre | Justus, C. G.. Auteur | 1980

Énergie éolienne / Franklin institute |

Énergie éolienne / Franklin institute

Livre | 1980

Chargement des enrichissements...