Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Inverter Faults

Archive ouverte : Communication dans un congrès

Meinguet, Fabien | Nguyen, Ngac-Ky | Sandulescu, Paul | Kestelyn, Xavier | Semail, Eric

Edité par HAL CCSD ; IEEE

The authors would like to thank the ADEME for the funding of the MHYGALE project.. Multi-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of an open-end five-phase drive, i.e. a multi-phase machine fed with a dual-inverter supply. Open-circuit faults and inverter switch short-circuit faults are considered and handled with various degrees of reconfiguration. Theoretical developments and experimental results validate the proposed strategies.

Consulter en ligne

Suggestions

Du même auteur

Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives | Meinguet, Fabien

Signal-based Technique for Fault Detection and Isolation of Inverter Faults...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2012-12-17

International audience. A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitabl...

Different Virtual Stator Winding Configurations of Open-End Winding Five-Phase PM Machines for Wide Speed Range without Flux Weakening Operation | Nguyen, N.K

Different Virtual Stator Winding Configurations of Open-End Winding Five-Ph...

Archive ouverte: Communication dans un congrès

Nguyen, N.K | 2013-09-03

International audience. This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pe...

Flux-weakening operation of open-end winding drive integrating a cost effective high-power charger | Sandulescu, Paul

Flux-weakening operation of open-end winding drive integrating a cost effec...

Archive ouverte: Article de revue

Sandulescu, Paul | 2013-01

International audience. In this paper, a three-phase drive with a six-leg Voltage Source Inverter (VSI) and an open-end winding Interior Permanent Magnet Synchronous Machine (IPMSM) designed for the traction of an e...

Du même sujet

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Short-Circuit Inverter Fault | Nguyen, Ngac Ky

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with ...

Archive ouverte: Article de revue

Nguyen, Ngac Ky | 2015-01

International audience. Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuitfault, it is...

Different Virtual Stator Winding Configurations of Open-End Winding Five-Phase PM Machines for Wide Speed Range without Flux Weakening Operation | Nguyen, N.K

Different Virtual Stator Winding Configurations of Open-End Winding Five-Ph...

Archive ouverte: Communication dans un congrès

Nguyen, N.K | 2013-09-03

International audience. This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pe...

Comparison of five-phase, six-phase and seven-phase fault tolerant electric drives | Ribiere, Antonin

Comparison of five-phase, six-phase and seven-phase fault tolerant electric...

Archive ouverte: Communication dans un congrès

Ribiere, Antonin | 2022-06

International audience. Automotive industry is evolving towards more fault-tolerant actuators to fulfill future autonomous vehicles requirements. Critical applications such as steering or braking have to resist to f...

Electric Vehicles Driven by 5-phase Open-End Winding Machines Fed by Battery and Supercapacitors | Vu, Duc Tan

Electric Vehicles Driven by 5-phase Open-End Winding Machines Fed by Batter...

Archive ouverte: Communication dans un congrès

Vu, Duc Tan | 2019-10-15

International audience. This paper presents the modeling and control of an Electric Vehicle (EV) driven by a 5-phase Permanent Magnet Synchronous Machine (PMSM). The machine in an open-end winding configuration is s...

Eliminations of Low-frequency Current Harmonics for Five-phase Open-end Winding Non-sinusoidal Machine Drives applying Neural Networks | Vu, Duc Tan

Eliminations of Low-frequency Current Harmonics for Five-phase Open-end Win...

Archive ouverte: Communication dans un congrès

Vu, Duc Tan | 2020-10-18

International audience. This study aims at eliminating unwanted harmonics in current control of a five-phase non-sinusoidal permanent magnet synchronous machine (PMSM) in an open-end winding configuration. The machi...

Étude comparative de différents correcteurs pour la commande optimale avec défauts d'une machine pentaphasée | Mekri, Fatiha

Étude comparative de différents correcteurs pour la commande optimale avec ...

Archive ouverte: Article de revue

Mekri, Fatiha | 2012-04

La version éditeur de cet article est accessible à l'adresse suivante : doi:10.3166/ejee.15.377-400. International audience. The use of multiphase PM synchronous machines associated with VSI drives appears to be a v...