Low-frequency ultrasound skin mechanical impedance sensor for Pressure Ulcer diagnostic

Archive ouverte : Communication dans un congrès

Sales de Castro, Elis Marina | Semail, Betty | Giraud, Frédéric

Edité par HAL CCSD

National audience. Pressure ulcers are a concern not only for the patients who suffer from them, but also for public health. Its costs to the quality of life of patients and to the public finances can be reduced with an early diagnostic. Several efforts have been made to find a solution for this diagnostic, for example by analysing the hydration or the electrical impedance of the skin. So far, no method is sufficiently reliable. In this context, a low-frequency ultrasound device is proposed, with the aim of offering an alternative that can be reliable and non-invasive. The Langevin transducer is a highly efficient device that can provide a measurement of the mechanical characteristics of the skin. Initial results show that mechanical impedance can discriminate the skin according to the location of the measurement. . Les escarres représentent un problème sanitaire majeur non seulement pour les patients, mais aussi pour la santé publique. Ses couts pour la qualité de vie des patients et pour les finances publiques peuvent être réduits si son diagnostique se fait suffisamment tôt. Des nombreux efforts ont été faits en cherchant une solution pour ce diagnostique, en analysant l’hydratation ou l’impédance électrique de la peau, par exemple. Jusqu’à présent, aucune méthode n’est suffisamment fiable. Dans ce contexte, un dispositif de mesure d’impédance mécanique de la peau, utilisant des ultrasons de “basse fréquence”, est proposé, avec le but d’offrir une alternative qui peut-être fiable et non-invasive. Dans ce travail, nous proposons d’utiliser un transducteur de Langevin pour fournir une mesure des caractéristiques mécaniques de la peau. Des premiers résultats obtenus montrent que l’impédance mécanique permet de discriminer la peau selon la localisation de la mesure.

Consulter en ligne

Suggestions

Du même auteur

Low-frequency ultrasound device for pressure ulcer diagnosis

Archive ouverte: Communication dans un congrès

Sales de Castro, Elis Marina | 2022-09-14

International audience

Low Frequency Ultrasound Diagnostics Sensor for Pressure Ulcers

Archive ouverte: Communication dans un congrès

Sales de Castro, Elis Marina | 2021-10

International audience. Mechanical properties of skin are a clue for the diagnostic of pressure ulcers (PU) [1]. This project proposes a low-frequency ultrasound (LFU) device to identify the mechanical impedance (MI...

Vector Controlled Ultrasonic Transducer Applied to Soft Material Mechanical...

Archive ouverte: Communication dans un congrès

Sales de Castro, Elis Marina | 2021

International audience. The study of skin mechanical impedance is a clue to analyse its health. We use a Langevin Transducer at 60kHz to excite the skin. In return we observe the acoustic forces generated by the int...

Du même sujet

ECOS. 3, Toutes les situations de départ en 4 volumes. Dermatologie, maladi...

Livre | Bartolini, Arthur (19..-....) - auteur en médecine. Auteur | 2024

Guide diagnostique des troubles neurodéveloppementaux : méthode intégrative...

Livre | Haddar, Yazid (1975-....) - neuropsychologue. Auteur | 2023

"Ce guide s'appuie sur la méthode intégrative, qui prend en compte les 4 fonctions essentielles (cognitive, psychopathologique, adaptative et sensorielle) dans le cadre du bilan neuropsychologique pédiatrique. Elle insiste sur la ...

Vector Controlled Ultrasonic Transducer Applied to Soft Material Mechanical...

Archive ouverte: Communication dans un congrès

Sales de Castro, Elis Marina | 2021

International audience. The study of skin mechanical impedance is a clue to analyse its health. We use a Langevin Transducer at 60kHz to excite the skin. In return we observe the acoustic forces generated by the int...

Sémiologie médicale : l'apprentissage pratique de l'examen clinique / Bapti...

Livre | Coustet, Baptiste. Auteur | 2019 - 6e édition

L' évaluation diagnostique de l'enfant avec trouble du spectre de l'autisme...

Livre | Dormoy, Léa. Auteur | 2020

L' ECG facile / John Hampton,... Joanna Hampton,...

Livre | Hampton, John R.. Auteur | 2023 - 3e édition française, traduction de la 9e édition anglaise

Depuis 45 ans, L'ECG facile est considéré comme le guide pratique de référence pour comprendre et interpréter l'ECG. Cette 3e édition française est la traduction de la 9e édition anglaise, véritable best-seller sur le sujet. Il gu...

Chargement des enrichissements...