Vectorial Approach Based Control of a Seven-Phase Axial Flux Machine Designed for Fault Operation

Archive ouverte : Article de revue

Locment, Fabrice | Semail, Eric | Kestelyn, Xavier

Edité par HAL CCSD ; Institute of Electrical and Electronics Engineers

Version éditeur disponible à l'adresse suivante : http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4519973&isnumber=4636792. International audience. This paper deals with easy-to-implement control strategies when a seven-phase axial flux permanent magnet machine supplied by a seven-leg voltage source inverter is in fault operation mode. Using a vectorial multimachine description, a seven-phase machine presenting a heightened ability to be controlled with one or two open-circuited phases has been designed. The machine is first presented, and experimental results are provided when one or two phases are open circuited. Based on a vectorial approach, new current references are calculated to avoid high-torque ripples.

Consulter en ligne

Suggestions

Du même auteur

Fault Tolerant Multiphase Electrical Drives: The Impact of Design | Semail, Eric

Fault Tolerant Multiphase Electrical Drives: The Impact of Design

Archive ouverte: Article de revue

Semail, Eric | 2008-08

La version editeur de cet article est disponible à l'adresse suivante : http://journals.cambridge.org/action//displayFulltext?type=1&fid=8024174&jid=JAP&volumeId=43&issueId=02&aid=8024172&bodyId=&membershipNumber=&societyETOCSessi...

Predetermination of Currents and Field in Short-Circuit Voltage Operation for an Axial-Flux Permanent Magnet Machine | Henneron, Thomas

Predetermination of Currents and Field in Short-Circuit Voltage Operation f...

Archive ouverte: Communication dans un congrès

Henneron, Thomas | 2008-05

International audience. Risk of irreversible magnet demagnetization during short-circuit fault is analyzed in case of an axial-flux dual-rotor machine, using a three-dimensional finite-element method (3D-FEM). In or...

Identification of sensitive R-L parameters of a Multi-phase drive by a vector control | Bruyère, Antoine

Identification of sensitive R-L parameters of a Multi-phase drive by a vect...

Archive ouverte: Communication dans un congrès

Bruyère, Antoine | 2008-06

International audience. This paper focuses on an experimental method to determine the electric parameters of a seven-phase low-voltage multiphase drive. The drive is a belt driven starter-alternator for powerful car...

Du même sujet

Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives | Meinguet, Fabien

Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM ...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2011-06-28

International audience. This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered f...

A Method for Fault Detection and Isolation based on the Processing of Multiple Diagnostic Indices: Application to Inverter Faults in AC Drives | Meinguet, Fabien

A Method for Fault Detection and Isolation based on the Processing of Multi...

Archive ouverte: Article de revue

Meinguet, Fabien | 2013-05

International audience. A general method for fault detection and isolation is proposed and applied to inverter faults in drives of electric vehicles. This method is based on a change-detection algorithm, which allow...

Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives | Meinguet, Fabien

Signal-based Technique for Fault Detection and Isolation of Inverter Faults...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2012-12-17

International audience. A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitabl...

Control Strategies for Open-End Winding Drives Operating in the Flux-Weakening Region | Sandulescu, Paul

Control Strategies for Open-End Winding Drives Operating in the Flux-Weaken...

Archive ouverte: Article de revue

Sandulescu, Paul | 2013-09-23

International audience. This paper presents and compares control strategies for three-phase open-end winding drives operating in the flux-weakening region. A six-leg inverter with a single dc-link is associated with...

Flux-weakening operation of open-end winding drive integrating a cost effective high-power charger | Sandulescu, Paul

Flux-weakening operation of open-end winding drive integrating a cost effec...

Archive ouverte: Article de revue

Sandulescu, Paul | 2013-01

International audience. In this paper, a three-phase drive with a six-leg Voltage Source Inverter (VSI) and an open-end winding Interior Permanent Magnet Synchronous Machine (IPMSM) designed for the traction of an e...

Five-phase SPM machine with electronic pole changing effect for marine propulsion | Zahr, Hussein

Five-phase SPM machine with electronic pole changing effect for marine prop...

Archive ouverte: Communication dans un congrès

Zahr, Hussein | 2016-11

International audience. In this paper, the possibility of designing a five-phase Surface-mounted Permanent Magnet (SPM) machine with 20 slots and 8 poles for a low power marine propulsion system is examined. Due to ...

Chargement des enrichissements...