Corpus Callosum deformation analysis in Multiple Sclerosis

Archive ouverte : Article de revue

Derraz, Foued | Pinti, Antonio | Lenne, Bruno | Peyrodie, Laurent | Chikh, Azzeddine | Taleb-Ahmed, Abdelmalik | Hautecoeur, Patrick

Edité par HAL CCSD

nombre de pages : 15. International audience. In this paper, we propose a new methodology for analyzing the deformations of the Corpus Callosum (CC) volume associated to Multiple Sclerosis (MS) lesion. We propose an approach for 3D segmentation of the volume of interest based on deformable models method. The measures are carried from the segmented brain volume obtained from MR and the deformation of the geometric shape is quantified. The deformations of the two ends as well as the thickness of the CC were retained to validate the method. The results allow evaluating the rate of deformation of the CC among patients from MRI sequences of patients with different level from handicap using the criterion established in this paper.

Consulter en ligne

Suggestions

Du même auteur

Semi-automatic Segmentation of Multiple Sclerosis Lesion Based Active Contours Model and Variational Dirichlet Process' | Derraz, Foued

Semi-automatic Segmentation of Multiple Sclerosis Lesion Based Active Conto...

Archive ouverte: Article de revue

Derraz, Foued | 2010-10

International audience. We propose a new semi-automatic segmentation based Active Contour Model and statistic prior knowledge of Multiple Sclerosis (MS) Lesions in Regions Of Interest (RIO) within brain Magnetic Res...

Impaired recognition of facial emotional expressions in Multiple Sclerosis | Lenne, Bruno

Impaired recognition of facial emotional expressions in Multiple Sclerosis

Archive ouverte: Article de revue

Lenne, Bruno | 2014-04

International audience

Development of CBCT-based prostate setup correction strategies and impact of rectal distension | Boydev, Christine

Development of CBCT-based prostate setup correction strategies and impact o...

Archive ouverte: Article de revue

Boydev, Christine | 2015

International audience. Background: Cone-beam computed tomography (CBCT) image-guided radiotherapy (IGRT) systems are widely used tools to verify and correct the target position before each fraction, allowing to max...

Du même sujet

Semi-automatic Segmentation of Multiple Sclerosis Lesion Based Active Contours Model and Variational Dirichlet Process' | Derraz, Foued

Semi-automatic Segmentation of Multiple Sclerosis Lesion Based Active Conto...

Archive ouverte: Article de revue

Derraz, Foued | 2010-10

International audience. We propose a new semi-automatic segmentation based Active Contour Model and statistic prior knowledge of Multiple Sclerosis (MS) Lesions in Regions Of Interest (RIO) within brain Magnetic Res...

Precoded Large Scale Multi‐User‐MIMO System Using Likelihood Ascent Search for Signal Detection | Bagadi, Kalapraveen

Precoded Large Scale Multi‐User‐MIMO System Using Likelihood Ascent Search ...

Archive ouverte: Article de revue

Bagadi, Kalapraveen | 2022

International audience. Multiple antennas at each User Equipment (UE) and/or thousands of antennas at the Base Station comprise the extremely spectrum efficient large scale Multi-User Multiple Input Multiple Output ...

Expanded Disability Status Scale (EDSS) estimation in multiple sclerosis from posturographic data | Cao, Hua

Expanded Disability Status Scale (EDSS) estimation in multiple sclerosis fr...

Archive ouverte: Article de revue

Cao, Hua | 2013-02-01

International audience. Expanded Disability Status Scale (EDSS) is the most widely used clinical scale to evaluate levels of multiple sclerosis (MS). As MS can lead to disruptions in the regulation of balance and th...

Improvements of Adaptive Filtering by Optimal Projection to filter different artifact types on long duration EEG recordings | Boudet, Samuel

Improvements of Adaptive Filtering by Optimal Projection to filter differen...

Archive ouverte: Article de revue

Boudet, Samuel | 2012-10-02

International audience. Adaptive Filtering by Optimal Projection (AFOP) is an automatic method for reducing ocular and muscular artifacts on electro-encephalographic (EEG) recordings. This paper presents two additio...

A robust method to filter various types of artifacts on long duration EEG recordings | Boudet, Samuel

A robust method to filter various types of artifacts on long duration EEG r...

Archive ouverte: Communication dans un congrès

Boudet, Samuel | 2008-05-16

International audience. EEG is a system used to measure electrical brain activity using multiple electrodes placed on the scalp. Unfortunately, the signals can be easily contaminated by noises called artifacts. Thes...

A change-detection algorithm for short-circuit fault detection in closed-loop AC drives | Meinguet, Fabien

A change-detection algorithm for short-circuit fault detection in closed-lo...

Archive ouverte: Article de revue

Meinguet, Fabien | 2014

The authors would like to thank the Belgian F.R.I.A. for the funding of this research project. International audience. This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-vo...

Chargement des enrichissements...