Extension of the crosstalk cancellation method in ultrasonic transducer arrays from the harmonic regime to the transient one

Archive ouverte : Article de revue

Bybi, Abdelmajid | Grondel, Sébastien | Assaad, Jamal | Hladky, Anne-Christine

Edité par HAL CCSD ; Elsevier

International audience. This paper describes a procedure to extend the crosstalk correction method presented in a previous paper [A. Bybi, S. Grondel, J. Assaad, A.–C. Hladky-Hennion, M. Rguiti, Reducing crosstalk in array structures by controlling the excitation voltage of individual elements: a feasibility study, Ultrasonics, 53 (6) (2013) 1135–1140] from the harmonic regime to the transient one. For this purpose a part of an ultrasonic transducer array radiating in water is modeled around the frequency 0.5 MHz using the finite element method. The study is carried out at low frequency in order to respect the same operating conditions than the previous paper. This choice facilitated the fabrication of the transducer arrays and the comparison of the numerical results with the experimental ones. The modeled array is composed of seventeen elements with the central element excited, while the others are grounded. The matching layers and the backing are not taken into account which limits the crosstalk only to the piezoelectric elements and fluid. This consideration reduces the structure density mesh and results in faster computation time (about 25 min for each configuration using a computer with a processor Intel Core i5-3210M, frequency 2.5 GHz and having 4 Go memory (RAM)).The novelty of this research work is to prove the efficiency of the crosstalk correction method in large frequency band as it is the case in medical imaging. The numerical results show the validity of the approach and demonstrate that crosstalk can be reduced by at least 13 dB in terms of displacement. Consequently, the directivity pattern of the individual element can be improved.

Consulter en ligne

Suggestions

Du même auteur

Numerical study of the cross-talk effects in acoustical transducer arrays and correction | Bybi, Abdelmajid

Numerical study of the cross-talk effects in acoustical transducer arrays a...

Archive ouverte: Communication dans un congrès

Bybi, Abdelmajid | 2013-06-02

International audience. Cross-talk in acoustical transducer arrays is an undesirable phenomenon which decreases seriously the performances of these arrays. Indeed, when one element of the array is driven, it generat...

Reducing crosstalk in array structures by controlling the excitation voltage of individual elements : a feasibility study | Bybi, Abdelmajid

Reducing crosstalk in array structures by controlling the excitation voltag...

Archive ouverte: Article de revue

Bybi, Abdelmajid | 2013

International audience. This paper describes a procedure to minimize crosstalk between the individual elements of a piezoelectric transducer array. A two-dimensional finite elements model was developed and the excit...

Étude et correction du couplage inter-éléments dans les réseaux de transducteurs ultrasonores | Bybi, Abdelmajid

Étude et correction du couplage inter-éléments dans les réseaux de transduc...

Archive ouverte: Communication dans un congrès

Bybi, Abdelmajid | 2011

National audience

Du même sujet

Cross-coupling cancellation in transducer arrays | Bybi, Abdelmajid

Cross-coupling cancellation in transducer arrays

Archive ouverte: Communication dans un congrès

Bybi, Abdelmajid | 2010

International audience

Investigation of cross-coupling in piezoelectric transducer arrays and correction | Bybi, Abdelmajid

Investigation of cross-coupling in piezoelectric transducer arrays and corr...

Archive ouverte: Article de revue

Bybi, Abdelmajid | 2019-10

International audience. Cross-coupling in piezoelectric transducer arrays is an undesirable phenomenon which decreases the performance of these devices. Indeed, when one element of a transducer is driven, it generat...

Numerical study of the cross-talk effects in acoustical transducer arrays and correction | Bybi, Abdelmajid

Numerical study of the cross-talk effects in acoustical transducer arrays a...

Archive ouverte: Communication dans un congrès

Bybi, Abdelmajid | 2013-06-02

International audience. Cross-talk in acoustical transducer arrays is an undesirable phenomenon which decreases seriously the performances of these arrays. Indeed, when one element of the array is driven, it generat...

Development of broadband high-frequency piezoelectric micromachined ultrasonic transducer array | Wang, Xu-Bo

Development of broadband high-frequency piezoelectric micromachined ultraso...

Archive ouverte: Article de revue

Wang, Xu-Bo | 2021

International audience. Piezoelectric micromachined ultrasonic transducers (PMUT) are promising elements to fabricate a two-dimensional (2D) array with a pitch small enough (approximately half wavelength) to form an...

Development of backing piezoelectric micromachined ultrasonic transducer (B-PMUT) 2D array | Wang, Xu-Bo

Development of backing piezoelectric micromachined ultrasonic transducer (B...

Archive ouverte: Communication dans un congrès

Wang, Xu-Bo | 2021-09-11

International audience. To improve the problem of narrow bandwidth and large crosstalk in high-frequency PMUT array, a PMUT device with a damping backing structure (B-PMUT) is proposed and realized. The device is a ...

Reducing crosstalk in array structures by controlling the excitation voltage of individual elements : a feasibility study | Bybi, Abdelmajid

Reducing crosstalk in array structures by controlling the excitation voltag...

Archive ouverte: Article de revue

Bybi, Abdelmajid | 2013

International audience. This paper describes a procedure to minimize crosstalk between the individual elements of a piezoelectric transducer array. A two-dimensional finite elements model was developed and the excit...

Chargement des enrichissements...