0 avis
An approach to model shaft voltage of wound rotor synchronous machines
Archive ouverte : Communication dans un congrès
Edité par HAL CCSD
International audience. In the case of high power synchronous machines, shaft voltage can induce high currents yielding to bearing damages but it can also constitutes a variable to be used to diagnosis some machine defects. Therefore, it is important to well model the phenomenon in order to use it in further diagnosis tool. Index Terms-Fault diagnosis, finite element model, shaft voltage, synchronous generator.