Inverter Fault Diagnosis of an Electrical Series-Connected Two Sinusoidal Six-Phase Permanent Magnet Machines Drive

Archive ouverte : Article de revue

Jose dos Santos Moraes, Tiago | Trabelsi, Mohamed | Nguyen, N.K. | Semail, Eric | Meinguet, Fabien

Edité par HAL CCSD ; Institution of Engineering and Technology

International audience. This paper investigates a real-time fault diagnostic of a transportation system which needs two drives with fault-tolerance capabilities. Because of constraints on the mass of the system and on the cost of the Voltage Source Inverter (VSI), a drive with two Six-Phase Permanent Magnet Synchronous Machines (PMSM) in series-connection supplied by two six-leg inverters is chosen. Despite the serial -connection, independent control of the two machines and fault –tolerance to open-switch fault is ensured. Nevertheless, a Fault Detection Identification (FDI) process is required for analysis and/or control reconfiguration. The proposed FDI is based on the combination of different criteria obtained from the two zero-sequence currents and from the normalized currents mapped into two frames defined by the Concordia Transformation. Results obtained from simulation and experimental tests show the effectiveness of the proposal.

Consulter en ligne

Suggestions

Du même auteur

Demagnetization analysis of an open-end windings 5-phase PMSM under transistor short-circuit fault | dos Santos Moraes, Tiago José

Demagnetization analysis of an open-end windings 5-phase PMSM under transis...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2019-10-14

International audience. For an open-end windings integrated Permanent Magnet Synchronous Machine, the demagnetization of the permanent magnets is analyzed when a transistor is short-circuited and no specific control...

Homopolar Current’s Copper Losses Analysis for Different Modulations in Open-End Winding Five-Phase drives | dos Santos Moraes, Tiago José

Homopolar Current’s Copper Losses Analysis for Different Modulations in Ope...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2018-09-03

International audience. This paper analyses the copper losses due to the homopolar current of a five-phase open-end winding machine supplied by a 10-leg inverter and a single DC voltage source. This topology can hav...

A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under Short-Circuit Inverter Switch Fault | dos Santos Moraes, Tiago José

A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2015-06

International audience. This paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in...

Chargement des enrichissements...