Low-frequency ultrasound skin mechanical impedance sensor for Pressure Ulcer diagnostic

Archive ouverte : Communication dans un congrès

Sales de Castro, Elis Marina | Semail, Betty | Giraud, Frédéric

Edité par HAL CCSD

National audience. Pressure ulcers are a concern not only for the patients who suffer from them, but also for public health. Its costs to the quality of life of patients and to the public finances can be reduced with an early diagnostic. Several efforts have been made to find a solution for this diagnostic, for example by analysing the hydration or the electrical impedance of the skin. So far, no method is sufficiently reliable. In this context, a low-frequency ultrasound device is proposed, with the aim of offering an alternative that can be reliable and non-invasive. The Langevin transducer is a highly efficient device that can provide a measurement of the mechanical characteristics of the skin. Initial results show that mechanical impedance can discriminate the skin according to the location of the measurement. . Les escarres représentent un problème sanitaire majeur non seulement pour les patients, mais aussi pour la santé publique. Ses couts pour la qualité de vie des patients et pour les finances publiques peuvent être réduits si son diagnostique se fait suffisamment tôt. Des nombreux efforts ont été faits en cherchant une solution pour ce diagnostique, en analysant l’hydratation ou l’impédance électrique de la peau, par exemple. Jusqu’à présent, aucune méthode n’est suffisamment fiable. Dans ce contexte, un dispositif de mesure d’impédance mécanique de la peau, utilisant des ultrasons de “basse fréquence”, est proposé, avec le but d’offrir une alternative qui peut-être fiable et non-invasive. Dans ce travail, nous proposons d’utiliser un transducteur de Langevin pour fournir une mesure des caractéristiques mécaniques de la peau. Des premiers résultats obtenus montrent que l’impédance mécanique permet de discriminer la peau selon la localisation de la mesure.

Consulter en ligne

Suggestions

Du même auteur

Low-frequency ultrasound device for pressure ulcer diagnosis | Sales de Castro, Elis Marina

Low-frequency ultrasound device for pressure ulcer diagnosis

Archive ouverte: Communication dans un congrès

Sales de Castro, Elis Marina | 2022-09-14

International audience

Low Frequency Ultrasound Diagnostics Sensor for Pressure Ulcers | Sales de Castro, Elis Marina

Low Frequency Ultrasound Diagnostics Sensor for Pressure Ulcers

Archive ouverte: Communication dans un congrès

Sales de Castro, Elis Marina | 2021-10

International audience. Mechanical properties of skin are a clue for the diagnostic of pressure ulcers (PU) [1]. This project proposes a low-frequency ultrasound (LFU) device to identify the mechanical impedance (MI...

Vector Controlled Ultrasonic Transducer Applied to Soft Material Mechanical Impedance Estimation | Sales de Castro, Elis Marina

Vector Controlled Ultrasonic Transducer Applied to Soft Material Mechanical...

Archive ouverte: Communication dans un congrès

Sales de Castro, Elis Marina | 2021

International audience. The study of skin mechanical impedance is a clue to analyse its health. We use a Langevin Transducer at 60kHz to excite the skin. In return we observe the acoustic forces generated by the int...

Du même sujet

ECOS. 3, Dermatologie, maladie infectieuse, médecine interne, pharmacologie, santé publique : Toutes les situations de départ en 4 volumes / Arthur Bartolini, Clara Kacel | Bartolini, Arthur (19..-....) - auteur en médecine. Auteur

ECOS. 3, Dermatologie, maladie infectieuse, médecine interne, pharmacologie...

Livre | Bartolini, Arthur (19..-....) - auteur en médecine. Auteur | 2024

60 ECOS – R2C thérapeutique / Collège national des enseignants de thérapeutique | Daumas, Aurélie (1982-...). Directeur de publication

60 ECOS – R2C thérapeutique / Collège national des enseignants de thérapeut...

Livre | Daumas, Aurélie (1982-...). Directeur de publication | 2023

Les ECOS (Examens Cliniques Objectifs Structurés) – nouvelle épreuve de la réforme du 2e cycle des études de médecine (R2C) – sont un des éléments clés permettant votre classement national en fin de 6e année. L'ECOS évalue vos per...

Vector Controlled Ultrasonic Transducer Applied to Soft Material Mechanical Impedance Estimation | Sales de Castro, Elis Marina

Vector Controlled Ultrasonic Transducer Applied to Soft Material Mechanical...

Archive ouverte: Communication dans un congrès

Sales de Castro, Elis Marina | 2021

International audience. The study of skin mechanical impedance is a clue to analyse its health. We use a Langevin Transducer at 60kHz to excite the skin. In return we observe the acoustic forces generated by the int...

DSM-5® : manuel diagnostique et statistique des troubles mentaux / American psychiatric association | Crocq, Marc-Antoine (19..-....) - psychiatre. Traducteur. Directeur de publication

DSM-5® : manuel diagnostique et statistique des troubles mentaux / American...

Livre | Crocq, Marc-Antoine (19..-....) - psychiatre. Traducteur. Directeur de publication | 2015 - 5e édition

Sémiologie médicale : l'apprentissage pratique de l'examen clinique / Baptiste Coustet | Coustet, Baptiste. Auteur

Sémiologie médicale : l'apprentissage pratique de l'examen clinique / Bapti...

Livre | Coustet, Baptiste. Auteur | 2019 - 6e édition

DSM-IV-TR : cas cliniques / Robert L. Spitzer, Miriam Gibbon, Andrew E. Skodol... [et al.] | Crocq, Marc-Antoine (19..-....) - psychiatre. Traducteur

DSM-IV-TR : cas cliniques / Robert L. Spitzer, Miriam Gibbon, Andrew E. Sko...

Livre | Crocq, Marc-Antoine (19..-....) - psychiatre. Traducteur | 2008

Chargement des enrichissements...