Demagnetization analysis of an open-end windings 5-phase PMSM under transistor short-circuit fault

Archive ouverte : Communication dans un congrès

dos Santos Moraes, Tiago José | Semail, Eric | Nguyen, Ngac-Ky

Edité par HAL CCSD ; IEEE

International audience. For an open-end windings integrated Permanent Magnet Synchronous Machine, the demagnetization of the permanent magnets is analyzed when a transistor is short-circuited and no specific control strategy is adopted. Depending on the temperature, the high currents due to the inverter fault may locally demagnetized the permanent magnets leading to an accelerated aging of the machine and torque loss. A co-simulation, using a Finite Element software for the machine coupled with an average modeling of the transistor, gives interesting local prediction of the machine behavior in healthy and degraded mode.

Consulter en ligne

Suggestions

Du même auteur

A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2015-06

International audience. This paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in...

A Comparative Study of Two Fault-Tolerant Dual-Motor Drive Topologies Under...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2015-06

International audience. This paper analyzes two dual-motor fault-tolerant topologies for aerospace thruster application. The first structure supplies independently both machines while the second one connects them in...

Homopolar Current’s Copper Losses Analysis for Different Modulations in Ope...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2018-09-03

International audience. This paper analyses the copper losses due to the homopolar current of a five-phase open-end winding machine supplied by a 10-leg inverter and a single DC voltage source. This topology can hav...

Du même sujet

Inverter Open Circuit Faults Diagnosis in Series-Connected Six-Phases Perma...

Archive ouverte: Communication dans un congrès

dos Santos Moraes, Tiago José | 2017-08

This work is a part of a project CE2I supported by FEDER and by the regional council of Hauts de France Region. It has been also supported by Thales Alenia Space.. International audience. This paper deals with the f...

Electric Vehicles Driven by 5-phase Open-End Winding Machines Fed by Batter...

Archive ouverte: Communication dans un congrès

Vu, Duc Tan | 2019-10-15

International audience. This paper presents the modeling and control of an Electric Vehicle (EV) driven by a 5-phase Permanent Magnet Synchronous Machine (PMSM). The machine in an open-end winding configuration is s...

Open-Switch and Open-Phase Real Time FDI Process for Multiphase PM Synchron...

Archive ouverte: Communication dans un congrès

Nguyen, Ngac Ky | 2016-06

This paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric drive...

Comparison of two battery/supercapacitors architectures for electric vehicl...

Archive ouverte: Communication dans un congrès

Castaings, Ali | 2017-07-04

ELECTRIMACS 2017, TOULOUSE, FRANCE, 04-/07/2017 - 06/07/2017. Batteries have been associated with supercapacitors in some vehicle applications. This has been done to face the batteries limitations in terms of power ...

Comparison of Technical Features between a More Electric Aircraft and a Hyb...

Archive ouverte: Communication dans un congrès

Zhang, He | 2008-09-03

International audience