Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives

Archive ouverte : Communication dans un congrès

Meinguet, Fabien | Sandulescu, Paul | Aslan, Bassel | Lu, Li | Nguyen, Ngac-Ky | Kestelyn, Xavier | Semail, Eric

Edité par HAL CCSD ; IEEE - Institute of Electrical and Electronics Engineers

International audience. A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based on the unbalance of the phase currents and their instantaneous frequency. The method is applied to a five-phase permanent-magnet synchronous machine drive. Simulations and experiments validate the proposed method.

Consulter en ligne

Suggestions

Du même auteur

Computation of Optimal Current References for Flux-weakening of Multi-Phase Synchronous Machines | Lu, Li

Computation of Optimal Current References for Flux-weakening of Multi-Phase...

Archive ouverte: Communication dans un congrès

Lu, Li | 2012-10-25

International audience. Multi-phase synchronous machines are more and more used in specific applications where high power density, low bus voltage, wide speed range and fault-tolerant capabilities are required. Due ...

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Inverter Faults | Meinguet, Fabien

Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with ...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2013-12-10

The authors would like to thank the ADEME for the funding of the MHYGALE project.. Multi-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inve...

Different Virtual Stator Winding Configurations of Open-End Winding Five-Phase PM Machines for Wide Speed Range without Flux Weakening Operation | Nguyen, N.K

Different Virtual Stator Winding Configurations of Open-End Winding Five-Ph...

Archive ouverte: Communication dans un congrès

Nguyen, N.K | 2013-09-03

International audience. This paper presents a specific control strategy of double-ended inverter system for wide-speed range of open-winding five phase PM machines. Different virtual winding configurations (star, pe...

Du même sujet

A Method for Fault Detection and Isolation based on the Processing of Multiple Diagnostic Indices: Application to Inverter Faults in AC Drives | Meinguet, Fabien

A Method for Fault Detection and Isolation based on the Processing of Multi...

Archive ouverte: Article de revue

Meinguet, Fabien | 2013-05

International audience. A general method for fault detection and isolation is proposed and applied to inverter faults in drives of electric vehicles. This method is based on a change-detection algorithm, which allow...

Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives | Meinguet, Fabien

Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM ...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2011-06-28

International audience. This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered f...

Vectorial Approach Based Control of a Seven-Phase Axial Flux Machine Designed for Fault Operation | Locment, Fabrice

Vectorial Approach Based Control of a Seven-Phase Axial Flux Machine Design...

Archive ouverte: Article de revue

Locment, Fabrice | 2008-10

Version éditeur disponible à l'adresse suivante : http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4519973&isnumber=4636792. International audience. This paper deals with easy-to-implement control strategies ...

Control Strategies for Open-End Winding Drives Operating in the Flux-Weakening Region | Sandulescu, Paul

Control Strategies for Open-End Winding Drives Operating in the Flux-Weaken...

Archive ouverte: Article de revue

Sandulescu, Paul | 2013-09-23

International audience. This paper presents and compares control strategies for three-phase open-end winding drives operating in the flux-weakening region. A six-leg inverter with a single dc-link is associated with...

Multi-physics modeling of a permanent magnet synchronous machine by using lumped models | Bracikowski, N

Multi-physics modeling of a permanent magnet synchronous machine by using l...

Archive ouverte: Article de revue

Bracikowski, N | 2012

International audience. This paper describes the modeling of a permanent magnet synchronous machine by using lumped models. Designing electrical machines necessarily involves several fields of physics, such as elect...

Flux-weakening operation of open-end winding drive integrating a cost effective high-power charger | Sandulescu, Paul

Flux-weakening operation of open-end winding drive integrating a cost effec...

Archive ouverte: Article de revue

Sandulescu, Paul | 2013-01

International audience. In this paper, a three-phase drive with a six-leg Voltage Source Inverter (VSI) and an open-end winding Interior Permanent Magnet Synchronous Machine (IPMSM) designed for the traction of an e...

Chargement des enrichissements...