Vectorial Modeling and Control of Multiphase Machines with Non-salient Poles Supplied by an Inverter

Archive ouverte : Type de document indéfini

Kestelyn, Xavier | Semail, Eric

Edité par HAL CCSD ; Wiley

International audience. This chapter is devoted to the modeling and control of electrical machines having at least two independent statoric currents. The star-coupled three-phase machine without a neutral terminal or the triangle-coupled three-phase machine is the most basic of them. More precisely, the aim of this chapter is to emphasize the particularities created by a number of independent currents greater than two with respect to the classical three-phase machine.

Consulter en ligne

Suggestions

Du même auteur

Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives | Meinguet, Fabien

Signal-based Technique for Fault Detection and Isolation of Inverter Faults...

Archive ouverte: Communication dans un congrès

Meinguet, Fabien | 2012-12-17

International audience. A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitabl...

Generalized Vectorial Formalism – based multiphase series-connected motors control | Semail, Eric

Generalized Vectorial Formalism – based multiphase series-connected motors ...

Archive ouverte: Communication dans un congrès

Semail, Eric | 2015-10

Multiphase drives are more and more used in specific applications leading to a necessity of control strategy development. This paper presents the Generalized Vectorial Formalism (GVF) theory to control multiphase series-connected ...

Étude comparative de différents correcteurs pour la commande optimale avec défauts d'une machine pentaphasée | Mekri, Fatiha

Étude comparative de différents correcteurs pour la commande optimale avec ...

Archive ouverte: Article de revue

Mekri, Fatiha | 2012-04

La version éditeur de cet article est accessible à l'adresse suivante : doi:10.3166/ejee.15.377-400. International audience. The use of multiphase PM synchronous machines associated with VSI drives appears to be a v...

Du même sujet

Experimental Investigation of Inverter Open-Circuit Fault Diagnosis for Bi-Harmonic Five-Phase Permanent Magnet Drive | Trabelsi, Mohamed

Experimental Investigation of Inverter Open-Circuit Fault Diagnosis for Bi-...

Archive ouverte: Article de revue

Trabelsi, Mohamed | 2017

International audience. This paper proposes a procedure that is suitable for experimental investigation of real-time open-switch and open-phase faults diagnosis of a five-leg Voltage Source Inverter (VSI) feeding a ...

An Efficient Control of a Series Connected Two-Synchronous Motor 5-Phase with Non Sinusoidal EMF Supplied by a Single 5-leg VSI: Experimental and Theoretical Investigations | Mekri, Fatiha

An Efficient Control of a Series Connected Two-Synchronous Motor 5-Phase wi...

Archive ouverte: Article de revue

Mekri, Fatiha | 2012-11

International audience. This paper proposes the control scheme of an original drive which is made up of two 5-phase permanent magnet synchronous machines (PMSM) connected in series. Even if the Electro-Motive Forces...

Investigation on Model Predictive Control of a Five-Phase Permanent Magnet Synchronous Machine under Voltage and Current limits | Kestelyn, Xavier

Investigation on Model Predictive Control of a Five-Phase Permanent Magnet ...

Archive ouverte: Communication dans un congrès

Kestelyn, Xavier | 2015-03

The optimal control of electrical drives necessitates to take into account current and voltage limits that are imposed by the power electronics and the electrical machines. Let’s cite for example the flux-weakening operation of el...

Inverter Fault Diagnosis of an Electrical Series-Connected Two Sinusoidal Six-Phase Permanent Magnet Machines Drive | Jose dos Santos Moraes, Tiago

Inverter Fault Diagnosis of an Electrical Series-Connected Two Sinusoidal S...

Archive ouverte: Article de revue

Jose dos Santos Moraes, Tiago | 2020-03-08

International audience. This paper investigates a real-time fault diagnostic of a transportation system which needs two drives with fault-tolerance capabilities. Because of constraints on the mass of the system and ...

Two-Slot Coil Pitch For Five-Phase Integrated Permanent Magnet Synchronous Machine | Cousseau, R.

Two-Slot Coil Pitch For Five-Phase Integrated Permanent Magnet Synchronous ...

Archive ouverte: Communication dans un congrès

Cousseau, R. | 2020-08

International audience. This paper presents a simple method to size a concentrated winding permament magnet synchronous machine when a high number of slots is needed. A classical concentrated winding machine leads t...

Design Considerations of Five-Phase Machine with Double p/3p Polarity | Gong, Jinlin

Design Considerations of Five-Phase Machine with Double p/3p Polarity

Archive ouverte: Article de revue

Gong, Jinlin | 2018

International audience. In the context of traction drives with required torque transient capabilities and a classically wide flux weakening speed range, this paper gives design considerations of a particularDouble-P...

Chargement des enrichissements...